Assembly Details Gypsum Board 1" [25.4 mm] Sheetrock ® Gypsum Liner Panels (UL Type SLX) Steel Studs 2-1/2" [64 mm] CH studs, 20 ga. (0.033"), 24" [610 mm] O.C. Insulation 2-1/2" [64 mm] Knauf EcoBatt Insulation Gypsum Board 3 layers of 5/8" [15.9 mm] Sheetrock ® EcoSmart Gypsum Panel (UL Type ULIX ™) Notes View assembly information on UL Website.
Learn MoreUL Wall Assemblies, Fire Rated Wall Designs | USG
Wall Assemblies USG provides resources here for our UL wall assemblies for seamless integration into any construction project. These wall assembly files are used for planning and
Learn MoreGypsum Shaft Wall Systems
Elevator installation before, during or after 2 HOUR FIRE RATED. UL DESIGN U415. 3 1/2”. SHAFT SIDE. OFFICE SIDE. GYPSUM SHAFT WALL SYSTEMS
Learn More1 hour UL penetration for structural I-beam thru shaft wall
1 hour UL penetration for structural I-beam thru shaft wall I need a UL assembly for a structural I-beam penetrating thru a one-hour shaft wall. Access would only be from double layer (c side) side of wall. If possible, some variation of W-L-7188 steel I-beam, UL Penetration Assemblies 0 1 Reply Nathan Jennings 1 Year ago Hilti Verified Hi James,
Learn MoreAER-09038 - CEMCO
One-Hour Cavity Shaft Wall (Non-Load Bearing), See Figure 1 1. A minimum 2-1/2" wide 24 gauge floor and ceiling J-runners, attached to structure as described above. 4. 1" thick Sheetrock®Brand Gypsum Liner Panel- UL Type SLX, Friction
Learn MoreShaft Wall Solutions for Wood-Frame Buildings: Codes & Detailing - Civil
Several options for 1- and 2-hour fire resistance-rated, wood-frame wall assemblies that could be useful for shafts are presented below. 1-Hour Single Wall UL U305 GA WP 3510 UL U311 IBC Table 721.1 (2), Item 14-1.3 UL U332 1-Hour Double Wall UL U341 2-Hour Single wall UL U301 UL U334 IBC Table 721.1 (2) Item Number 14-1.5
Learn MorePDF Shaftwall & Stairwell Systems - PABCO GypsumPDF
installation from a single side—no need for scaffolding within the shaft, and a cost effective solution. PABCO Wall Assembly diagram of 2‐Hour Shaftwall System angles to studs with 1" Type S screws 24" o.c. UL Design U 429 allows use of 5/8" FLAME CURB® Type C, 4'
Learn MoreExterior Wall System Testing and Certification | UL Solutions
Meet exterior wall system requirements Exterior wall assemblies are designed to resist the impacts of fire, wind, rain, hail, extreme temperatures and sound, and be energy efficient, attractive and much more. We understand these challenges. We provide testing, inspection, and certification solutions for exterior wall assemblies.
Learn MoreWhat You Should Know About Cavity Shaftwalls
Can horizontal shaftwall assemblies be used for a rated corridor ceiling? National Gypsum's UL Cavity Shaftwall Systems (1-4 hour)
Learn MoreShaft Wall Solutions For Wood-Frame Buildings - WoodWorks
were to fail at 1 hour, the wall above could not continue UL U334. FIGURE 5: Shaftliner Wall Assembly with Wood Wall Each Side. FIGURE 6:.
Learn MoreCavity Shaft Wall - USG
The Cavity Shaft Wall System includes components that provide the strength to withstand lateral loads and fire protection necessary for walls that enclose elevator shafts, stairwells and other vertical shafts. The system includes gypsum liner panels, gypsum panels and cement board, interior finishing products and framing components. Main Features
Learn MoreUL Design U415 - 1, 2, 3, or 4 Hour Wall Assembly - BuildSite
UL Design U415 - 1, 2, 3, or 4 Hour Wall Assembly Documents (1) Add to Package Installation Instructions - UL Design U415 - 1, 2, 3, or 4 Hour Wall Assembly (454 Kb, 11pg) System
Learn MoreDesign No. U417 Nonbearing Wall Ratings — 1, 2 or 3 Hr
Indicates such products shall bear the UL or cUL Certification Mark for For use with Type Shaftliner liner panels - Gypsum panels,
Learn MoreUL U415 System A - Wall Assembly - Knauf Insulation North America
UL U415 System A — Shaft Wall, Steel Stud (Non-Load-Bearing) Products Products > Pipe Insulation. Batts. UL Wall Assemblies BIM - Revit Library Transparency Catalog > NAIMA 3E Plus Fire Rating 1 Hour; System Thickness 4.00000-5/8" PDF
Learn MoreUL Design U469 - 1 Hour Wall Assembly - BuildSite
UL Design U469 - 1 Hour Wall Assembly Documents (1) Add to Package Installation Instructions - UL Design U469 - 1 Hour Wall Assembly (96 Kb, 5pg) System Package Hide Steel Studs "C-H"
Learn MoreShaftwall & Stairwell Systems - PABCO Gypsum
1” PABCORE® Shaftliner, Type X 1” (25.4mm) 24” (610mm) 8’ (2428mm) 10’ (3048mm) 12’ (3658mm) Double Beveled 4.1 lbs/ft2 N/A 1” MOLD CURB® Plus Shaftliner, Type X 1” (25.4mm) 24” (610mm) 8’ (2428mm) 10’ (3048mm) 12’ (3658mm) Double Beveled 4.1 lbs/ft2 10 (Highest Rating) 1” PABCO GLASS® Shaftliner, Type X
Learn MoreUL-Classified Head of Wall Assembly Fire Ratings
Fire-resistance ratings have long been used by UL and the building codes to Wall Assembly — The 1 hr or 2 hr fire rated gypsum board/steel stud wall
Learn MoreBXUV.U415 - Fire-resistance Ratings - ANSI/UL 263 - BuildSite
Fire resistance assemblies and products are developed by the design submitter and have been Nonbearing Wall Ratings — 1, 2, 3 or 4 Hr.
Learn MoreUSG Head of Shaft Wall Details Fire Resistant Assemblies - J2131
Scale: 3" = 1' - 0" 2 HR HEAD OF WALL UL HW-D-0603 4 Scale: 3" = 1' - 0" 2 HR HEAD OF WALL ADJACENT TO BEAM 3 STRUCTURAL SLAB STEEL BEAM WITH FIREPROOFING 6" MAX
Learn MoreIs the Horizontal Shaft Wall UL tested? - USG
Is the Horizontal Shaft Wall UL tested? While not tested by UL, the system has been tested for fire and is covered for use throughout the United States. The fire test number is WHI 495-PSH-0154/0167 and report number is AER-09038 available at www.p-e-i.com.
Learn MoreClarkDietrich Shaftwall Systems
2 Hour Wall with (2) layers 5/8" Type X + (1) 1" Shaft Liner · Dead Load of assembly ONLY is considered. · Not designed to carry any Live Loads, Mechanical
Learn MoreBXUV.U499 Fire Resistance Ratings - ANSI/UL 263 - SCAFCO
4/26 · Fire Resistance Ratings - ANSI/UL 263 See General Information for Fire Resistance Ratings - ANSI/UL 263 Design No. U499 April 26, Nonbearing Wall Rating — 1 Hr. 1. Channel Track — "J" -shaped channel, 2-1/2 in. deep with unequal legs of 1 in. and 2
Learn MorePDF Cgc Shaft Wall Systems - UsgPDF
CGC Shaft Wall Systems are non-load-bearing gypsum wall partition assemblies constructed from outside the shaft at each floor. Shafts are enclosed early in construction, and the walls are finished later, along with interior partitions. Installation is quick and easy, using components and application procedures familiar to drywall contractors.
Learn MoreUl u529 shaft wall - zsi.szaffer.pl
A 2-hour fire-resistive, non-load bearing non-combustible partition designed to enclose shaftwalls, containing elevators, ducts, piping, air shafts and similar construction applications. System consists of 1" shaftliner panels supported by 2-1/2", 4" or 6" C-T studs and faced on one side with two layers of 1/2" Type C or 5/8" Type X gypsum board.
Learn MoreFire Resistance - International Code Council
UL 263. ASTM. E119. Standards Used to Evaluate Assemblies Yes, this is a shaft wall. The rating – 1 Hour. ➢ The load capacity – Bearing. Wall
Learn MoreShaft Wall Solutions for Wood-Frame Buildings: Codes
Several options for 1- and 2-hour fire resistance-rated, wood-frame wall assemblies that could be useful for shafts are presented below. 1-Hour Single Wall UL U305 GA WP 3510 UL U311 IBC
Learn More